Step 152l-41
Did the system stop with the same error code as recorded in "Step 152l-1" on page 295?
Yes
The card just reinserted is defective. Replace it. This ends the procedure.
Return the system to its original configuration.
Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver pSeries Diagnostic Information
for Multiple Bus Systems.
No
Go to "Step 152l-42."
Step 152l-42
Have all the cards listed in "Step 152l-35" on page 299 been reinserted?
Yes
The symptom has changed. This ends the procedure.
Return the system to its original configuration.
Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver pSeries Diagnostic Information
for Multiple Bus Systems.
No
Go to "Step 152l-39" on page 299.
Step 152l-43
Turn off the power.
Examine the green "power good out" LEDs of both I/O subsystem DCAs.
Step 152l-44
Are all the green "power good out" LEDs of both I/O subsystem DCAs off?
Yes
Go to "Step 152l-45."
No
Call for support.
Step 152l-45
Replace the DCAs in the following list one at a time and in the order listed:
v DCA 1 at V1
v DCA 2 at V2
Step 152l-46
Turn on the power.
Step 152l-47
Did the system stop with the same error code as recorded in "Step 152l-1" on page 295?
Yes
Go to "Step 152l-48" on page 301.
No
The DCA just replaced is defective. This ends the procedure.
Return the system to its original configuration.
Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver pSeries Diagnostic Information
for Multiple Bus Systems.
300
Eserver pSeries 690 Service Guide