Error Code Description
4605 2738 I/O subsystem and display alter tests detected
fault in I/O book 1, 3, or 4
4605 273C I/O subsystem and display alter tests detected
fault in primary I/O book - Slot 0
4605 273D I/O subsystem and processor subsystem tests
detected fault in primary I/O book - Slot 0
4605 273F SMA 2-port switch adapter fault
4605 2776 I/O subsystem and processor subsystem tests
detected fault in I/O book 1, 3, or 4
4605 2806 I/O subsystem and processor subsystem tests
detected fault in I/O book 1, 3, or 4
4605 28B0 I/O subsystem and display alter tests detected
fault in I/O subsystem PCI backplane
4605 28B1 I/O subsystem and display alter tests detected
fault in I/O subsystem DASD backplane
4605 525E CUoD capacity card fault
4605 525F CUoD capacity card fault
4605 527A CUoD capacity card fault
714
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
Primary I/O book - Slot 0
Location: U1.18-P1-H2
Primary I/O book - Slot 0
Location: U1.18-P1-H2
Replace the I/O book (switch adapter) specified
by the location code.
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
I/O subsystem PCI backplane at location
specified in error code
I/O subsystem DASD backplane at location
specified in error code
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.