Step 152n-6
Are there any DASD in positions A8, A9, Aa, or Ab of the DASD backplane found in "Step 152n-2"
on page 306 and "Step 152n-3" on page 306?
Yes
Go to "Step 152n-7."
No
Go to "Step 152n-15" on page 308.
Step 152n-7
Record the DASD positions in slots A8, A9, Aa, or Ab, then remove any DASD in slots A8, A9, Aa, or Ab.
Note: You will be instructed in a later step to reinstall the DASD one at a time.
Turn on the power.
Step 152n-8
Did the error code recorded in "Step 152n-1" on page 306 reappear?
Yes
Go to "Step 152n-14."
No
One of the DASD just removed is defective. Go to "Step 152n-9."
Step 152n-9
Turn off the power. Make sure all green "power good out" LEDs of all installed I/O subsystem DCAs are
off.
Step 152n-10
Reinstall one of the DASD removed in "Step 152n-6."
Step 152n-11
Turn on the power.
Step 152n-12
Did the error code recorded in "Step 152n-1" on page 306 reappear?
Yes
The DASD just reinstalled is defective. Replace it. This ends the procedure. Return the system
to its original configuration.
Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver pSeries Diagnostic Information
for Multiple Bus Systems.
No
Go to "Step 152n-13."
Step 152n-13
Have all DASD that were removed in "Step 152n-6" been reinstalled?
Yes
The problem has changed. This ends the procedure.
No
Go to "Step 152n-9" to reinstall the next DASD.
Step 152n-14
Turn off the power. Make sure all green "power good out" LEDs of all installed I/O subsystem DCAs are
off.
Chapter 3. Maintenance Analysis Procedures
307