Reassemble the fuel piping and wiring connector to their original positions.
7
Turn the 3way fuel valve lever to the "B" side.
8
< Note >
 After reassembling, bleed air from the fuel system.
(Refer to section "9-3. Procedures during Operation".)
 After reassembling, check that there is no fuel leakage.
 Spill Containment Cleaning/Inspection
Use a high-pressure cleaner or similar equipment to clean the inside of the spill
1
containment.
2
Remove the drain plug (R1") to drain the cleaning water.
3
Check that there no rust has developed inside of the spill containment. If rust has
developed, remove the rust and clean again.
4
Tentatively, apply sealant coating to the plug (R1") or wrap it in seal tape and reinsert it.
Allow water to accumulate and check that the spill containment has no internal leakage.
5
Remove the drain plug (R1") to drain the water.
6
After the procedures have been completed, apply sealant coating to the plug (R1") or
7
wrap it in seal tape and reinsert it.
< Note >
 If the fluid drained when cleaning the spill containment
contains oil or grease, dispose of it according to the related
laws and regulations.
 If the spill containment has a leak, contact the authorized
distributor where the generator was purchased.
Position A
42
Position B
Drain Plug(R1")