Shindaiwa DGK25F Owner's And Operator's Manual page 40

Diesel engine generator
Hide thumbs Also See for DGK25F:
Table of Contents

Advertisement

(3) Air Filter Element Cleaning/Replacement
Clean
Every 250 hours
Replace
Every 500 hours
Remove the air cleaner clips and cleaner cap.
1
2
Remove the element.
Clean or replace the element. Attach by performing the above procedures in reverse
3
order.
< Note >
 Always be sure to turn the cleaner cap in the direction
indicated by the arrow.
 Replace the elements earlier if using in an excessively
dusty location.
 Do not add oil as this generator uses a dry element.
 Clear foreign material by pinching the vacuator valve once
a week in normal operating conditions or daily if operating
in a location that is excessively dirty or dusty. Wipe away
any dirt or moisture that has adhered to the parts.
 Never touch the elements for any reason except cleaning.
 Element part no.: P822768 (Isuzu part no.)
 Cleaning the air filter element
If dry dust is adhering : Blow compressed air from inside the element.
If carbon or oil is adhering : Replace with new parts.
(4) Draining Water from the Fuel Filter (Main and Pre-Filters)
Check/Drain
Drain water when the float (red) inside the cup floats to the
water draining position.
Set a container to catch spilled water.
1
Loosen the air bleeder plug of the fuel filter sufficiently.
2
Loosen the drain plug on the bottom to drain the water.
3
4
When water draining is completed, tighten the drain plug
on the bottom.
■Drain plug tightening torque :
1.5 to 2.5N・m(0.15 to 0.25kgf・m)
Tighten the air-bleeding plug.
5
■Air-bleeding plug tightening torque :
8 to 12N・m(0.8 to 1.2kgf・m)
Daily
37
Air Cleaner
Air Cleaner Cap
Air Filter Element
Air Cleaner Cap
Vacuator Valve
Main
Air Bleeder
Plug
Cup
Fuel Filter
Element
Float (Red)
Water Drain Level
Pre
Air Bleeder
Plug
Cup
Fuel Filter
Element
Float (Red)
Water Drain Level
Clip
Drain Plug
Drain Plug