Step
1.
Enter system view.
2.
Enable error packets diffusion
restraint.
3.
Configure error packets
diffusion restraint parameters.
Displaying and maintaining CT1 interfaces
Task
Display the status of a CT1
interface.
Display the status of a channel set.
Clear the controller counter for a
CE1 interface.
Configuring an E1-F interface
E1-F interfaces, which are fractional E1 interfaces, are simplified CE1 interfaces. They are a cost-effective
alternative to CE1 interfaces where E1 access does not need multiple channel sets.
An E1-F interface operating in framed mode can only bind timeslots into one channel set. A CE1
interface can group and bundle timeslots randomly into multiple channel sets.
An E1-F interface can operate in either framed (the default) or unframed mode.
When an E1-F interface is working in unframed mode, it is a non-timeslot interface with 2048 kbps of
data bandwidth. It is logically equivalent to a synchronous serial interface where you can configure PPP,
HDLC, or FR at the link layer and IP at the network layer.
When an E1-F interface is working in framed mode, it is physically divided into 32 timeslots numbered
0 through 31. Except timeslot 0 used for transmitting synchronization information, all other timeslots can
randomly form one channel set. The rate of the interface is n × 64 kbps and its logical features are the
same as those of a synchronous serial interface where you can configure PPP and FR at the data link layer
and IP at the network layer.
Configuring an E1-F interface in framed mode
Step
1.
Enter system view.
2.
Enter E1-F interface view.
Command
system-view
error-diffusion restraint enable
error-diffusion restraint config
detect-timer renew-timer threshold
Command
display controller t1 [ interface-number ] [ |
{ begin | exclude | include }
regular-expression ]
display interface serial
interface-number:set-number [ | { begin |
exclude | include } regular-expression ]
reset counters controller t1 interface-number
Command
system-view
interface serial interface-number
32
Remarks
N/A
N/A
Optional.
By default, the detect-timer is 30
seconds, the renew-timer is 600
seconds, and the PER threshold is
20%.
Remarks
Available in any view.
Available in any view.
Available in user view.
Remarks
N/A
N/A