Step
2.
Set the traffic polling interval
of the storm control module.
3.
Enter Ethernet interface view.
4.
Enable storm control, and set
the lower and upper
thresholds for broadcast,
multicast, or unknown unicast
traffic.
5.
Set the control action to take
when monitored traffic
exceeds the upper threshold.
6.
Enable the interface to send
storm control threshold event
traps.
7.
Enable the interface to log
storm control threshold events.
Configuring a Layer 3 Ethernet interface or
subinterface

Layer 3 Ethernet interface configuration task list

Perform the following configuration on Ethernet interfaces operating in route mode:
Task
Setting the MTU for an Ethernet interface or
subinterface
Configuring an Ethernet interface to operate in
promiscuous mode
Command
storm-constrain interval seconds
interface interface-type
interface-number
storm-constrain { broadcast |
multicast | unicast } { pps | kbps |
ratio } max-pps-values
min-pps-values
storm-constrain control { block |
shutdown }
storm-constrain enable trap
storm-constrain enable log
Remarks
Optional.
Applicable to Layer 3 Ethernet interfaces and Ethernet
subinterfaces.
Optional.
Applicable to Layer 3 Ethernet interfaces.
16
Remarks
Optional.
The default setting is 10 seconds.
N/A
By default, storm control is
disabled.
Optional.
No action is taken on an Ethernet
interface when a type of traffic
exceeds the upper storm control
threshold.
Optional.
By default, the interface sends
traps when monitored traffic
exceeds the upper threshold or
drops below the lower threshold
from the upper threshold.
Optional.
By default, the interface outputs log
messages when monitored traffic
exceeds the upper threshold or
falls below the lower threshold
from the upper threshold.