The EB-1 electrical junction box has been supplied
standard on the DV360/580 models to allow for the
easy installation of an optional fan kit.
To connect the EB-1 box to the house electrical supply,
follow the steps below.
1. Unscrew the retaining screw from the EB-1 base
plate (Fig. 9) and remove the EB-1 assembly from
the fireplace.
2. Remove the front cover of the EB-1 box.
3. Remove the plug socket assembly from the EB-1
box.
4. Feed the supply line in from the outside through the
cable clamp. (Fig. 9)
5. Connect black wire of the power supply line to the
brass screw (polarized) of the socket assembly.
6. Connect the white wire of the power line to the
chrome screw of the socket assembly.
7. Connect the ground wire of the supply line to the
green screw of the socket assembly.
8. Refit the socket assembly back into the electrical
box and replace the cover plate. Secure the cable
f i r e - p a r t s . c o m
with the clamp on the outside of the unit to prevent
strain on the connections.
9. The EB-1 electrical junction box is now ready to
supply power to the FK12 or FK24 fan kits if fitted.
INSIDE
OUTSIDE
Fig. 9 EB-1 receptacle.

Optional Top Vent Application

The DV360/580 fireplace is shipped as a rear vent unit.
If the layout requires a top vent, convert the unit follow-
ing the steps below.
1. Remove the 10 screws securing outer collar adapter
to fireplace. (Fig. 10)
2. Set outer collar adapter aside.
3. Remove insulation from top of unit and discard.
Remove the four (4) screws securing flue cover to
top of unit and remove flue cover. (Fig. 11)
DV580 Unit ONLY: Remove deflector top from unit
20002261
Vermont Castings Majestic Products DV360/580 Series
ELECTRICAL BOX
FP580
by squeezing together the two legs and allowing top
to fall into firebox. Discard. (Fig. 12)
4. Remove the four (4) screws securing flue pipe to
back of unit. Remove flue pipe. (Fig. 11)
5. Secure flue cover to back of flue outlet. Be sure to
replace gasket. (Fig. 13)
6. Install flue pipe and gasket removed in step 4 to top
of unit with four (4) screws. Be sure to replace
gasket. (Fig. 13)
7. Secure outer collar adapter to unit with the round
collar on top, secure with 10 screws.
NOTE: Be sure not to damage any gasket material.
Outer Collar
Adapter
Flue
Pipe
Remove
Screws (5)
Fig. 10 Remove screws from outer collar adapter.
Insulation
Flue
Cover
Flue
Pipe
Remove Screws (4)
Fig. 11 Remove flue cover and flue pipe.
CAUTION: Remove insulation. Insulation extends
beyond opening in top of unit. Be sure
to remove all insulation before complet-
ing conversion. Insulation measures
9¹⁄₄" x 22³⁄₄" (23.5cm x 57.8cm). If the unit
is converted back to a rear vent, the
insulation (Part number 20003129) must
be replaced.
Rear View
Remove
Screws
(5)
FP1030
Remove
Screws (4)
FP1027
9