External Modulating Control - Prestige Solo 110 Installation And Maintenance Manual

Table of Contents

Advertisement

13.0 External Modulating Control

HEATING SETTING
Heating Operation
Demand Type
Absolute Max CH Setpoint
CH1 Maximum Setpoint
CH1 Minimum Setpoint
Outdoor Curve Coldest Day
Outdoor Curve Warmest Day
CH2 Circuit
CH2 Maximum Setpoint
CH2 Minimum Setpoint
Warm Weather Shutdown
Circulation Pump Permanent
CH Post Pump Time
Freeze Protection
Frost Protection Setpoint
Parallel Shift Value
CH Call Blocking
DOMESTIC SETTING
DHW Operation
Demand Type
Boiler DHW Setpoint
DHW Setpoint
DHW On Differential
DHW Storage Adder
DHW Post Pump Time
DHW Priority Timeout
DHW Priority
DHW Call Blocking
DHW to CH Call Blocking
Antilegionella Function
BOILER SETTING
Prestige Model
Lockout Temp.
Modbus Address
Pump Settings
Ignition Level NAT
Factory ACVMax Setting
FACTORY DEFAULT
Enabled
Thermostat &
Outd. Curve
188°F [87°C]
180°F [82°C]
120°F [49°C]
0°F [-18°C]
64°F [18°C]
Enabled
140°F [60°C]
80°F [27°C]
OFF
Disabled
5 Minute
Enabled
-22°F [-30°C]
0°F [0°C]
1 Minute
FACTORY DEFAULT
Enabled
Thermostat (Solo)
Sensor (Excellence)
167°F [75°C]
140°F [60°C]
6°F [3°C]
28°F [15°C]
1 Minute
Off
Enabled
0 Minute
1 Minute
Disabled
FACTORY DEFAULT
Solo (2 pumps)
Solo/Excel. (3 way valve)
210°F [99°C]
0=BCST
Solo/Excellence 2
66
EZ SETUP RESET
EZ SETUP RESET
EZ SETUP RESET
INSTALLER RESET
INSTALLER RESET
INSTALLER RESET