Paxar Monarch 9855 Operator's Handbook Manual page 106

Rfid printer
Hide thumbs Also See for Monarch 9855:
Table of Contents

Advertisement

741
742
743
744
746
10-10 Diagnostics & Troubleshooting
Tag not found in RF field. The RFID tag was not found
in the RF field (area inside the printer where RFID tag
is programmed.) Check supply loading. When using
RFID supplies greater than a two-inch feed length,
make sure you have not adjusted the supply position.
When using RFID supplies with a one-inch feed length,
set the Print Position to +40 and the Supply Position to
-50. The printer does not recalibrate (feed a blank
label) after any RFID error. For more information, refer
to your RFID Application Notes.
Failed to erase tag. The RFID tag was found in the RF
field, but could not be erased. Increase the number of
retries. If this error occurs consecutively, increase or
decrease the attenuation setting by one. If the
attenuation is set too low, you may affect the data
programmed in adjacent labels.
Failed to program tag. The RFID tag was found in the
RF field, but could not be programmed. The printer
does not recalibrate (feed a blank label) after any RFID
error. For more information, refer to your RFID
Application Notes.
Tag already locked. The RFID tag is unable to be
programmed, because it is already locked. This is
considered a bad RFID tag. The printer does not
recalibrate (feed a blank label) after any RFID error.
For more information, refer to your RFID Application
Notes.
Failed to lock tag. The RFID tag has not been locked to
prevent reprogramming. This is considered a bad RFID
tag. The printer does not recalibrate (feed a blank
label) after any RFID error. For more information, refer
to your RFID Application Notes.