Parameters
10.2 Parameter list
Par. No.
Name
p29051[0..
Torque limit lower
.2]
Description: Negative torque limit.
Three internal torque limits in total are available.
You can select the internal parameters or the analog input as the source of the torque limit with the combina-
tion of the digital input signals TLIM1 and TLIM2.
p29060 *
Speed Scaling
Description: The scaling for the analog speed setpoint.
With this parameter, you can specify the speed setpoint corresponding to full analog input (10 V).
p29061
Offset Adjustment for
Analog input 1
Description: Offset adjustment for the analog input 1.
p29070[0..
Speed limit positive
.2] *
Description: Positive speed limit.
Three internal speed limits in total are available.
You can select the internal parameters or the analog input as the source of the speed limit with the combina-
tion of the digital input signals SLIM1 and SLIM2.
p29071[0..
Speed limit negative
.2] *
Description: Negative speed limit.
Three internal speed limits in total are available.
You can select the internal parameters or the analog input as the source of the speed limit with the combina-
tion of the digital input signals SLIM1 and SLIM2.
p29075
Speed Clamp Threshold
Description: The threshold for the zero speed clamp.
If the function of zero speed clamp has been enabled under the speed control mode, the motor speed is
clamped to 0 when both the setpoint speed and the actual speed are below this threshold.
p29078
Speed Reach Threshold
Description: Speed reached range (deviation between setpoint and motor speed)
p29080
Overload Threshold for
Output Signal Triggering
Description: Overload threshold for the output power.
p29090
Offset Adjustment for
Analog output 1
Description: Offset adjustment for analog output 1.
p29091
Offset Adjustment for
Analog output 2
Description: Offset adjustment for analog output 2.
p29110[0..
Position Loop Gain
.1] **
296
Min
Max
-300
150
6
210000
-0.50
0.50
0
210000
-210000
0
0
200
0.0
100.0
10
300
-0.50
0.50
-0.50
0.50
0.000
300.000
Factory
Unit
Data
Setting
type
-300
%
Float
3000
rpm
Float
0.00
V
Float
210000
rpm
Float
-
rpm
Float
210000
200
rpm
Float
10
rpm
Float
100
%
Float
0.00
V
Float
0.00
V
Float
[0]
100
Float
Motor
0/mi
de-
n
pendent
[1]
1.000
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2015, A5E36037884
Effective
Can be
changed
IM
T
IM
T
IM
T
IM
T
IM
T
IM
T
IM
T
IM
T
IM
T
IM
T
IM
T, U