Basic operator panel (BOP)
6.1 BOP overview
6.1.1

BOP display

Display
Example
8.8.8.8.8.8.
------
Fxxxxx
F.xxxxx.
Fxxxxx.
Axxxxx
A.xxxxx.
Axxxxx.
Rxxxxx
Pxxxxx
P.xxxxx
In xx
xxx.xxx
xxx.xx<>
xxxx.xx>
xxxx.xx<
S Off
Para
P 0x
144
Description
Drive is in startup state
Drive is busy
Fault code
Fault code of the first fault
Fault code
Alarm code
Alarm code of the first alarm
Alarm code
Parameter number
Parameter number
Parameter number
Indexed parameter
Negative parameter value
Current display can be moved to
left or right
Current display can be moved to
right
Current display can be moved to
left
Operating display: servo off
Editable parameter group
Parameter group
Remarks
In the case of a single fault
In the case of multiple faults
In the case of multiple faults
In the case of a single alarm
In the case of multiple alarms
In the case of multiple alarms
Read-only parameter
Editable parameter
Editable parameter; the dot means that at
least one parameter has been changed
Figure after "In" indicates the number of indi-
ces.
For example, "In 01" means that this indexed
parameter is 1.
Refer to the section "Change a parameter
value (Page 149)".
Six groups are available:
1. P0A: basic
2. P0B: gain adjustment
3. P0C: speed control
4. P0D: torque control
5. P0E: position control
6. P0F: IO
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2015, A5E36037884