Align the plate to the graphics board assembly, and then insert both tabs between the heat
2.
spreader and process control board. Do not move the plate.
Install the M2.5x6 mm flat head screws through the plate hole alignment to the baseplate. Do not
3.
apply any torque. Slightly tighten only by hand.
If the screws lack Nylok coating or are used, add Loctite 242 Threadlocker 3~5 threads from the
tip.
Install the M2.5x6 mm wafer head screws (removed earlier) through the heat spreader, plate tab,
4.
and process control board hole alignment to the baseplate. Torque both screws to 4.0~4.5 in-lbf.
Removal and replacement procedures 45