System Components

* Bleed Type Master Air Valve (B)
Trapped air can cause the pump to cycle unexpectedly,
which could result in serious injury from splashing or
moving parts.
Be sure the valve is easily accessible from the pump
and located downstream from the air regulator.
Required in your system to relieve air trapped
between it and the air motor when the valve is
closed.
Open to supply air to the motor.
Close to shut off air to the motor, and bleed any
trapped air from the motor.
* Air Pressure Relief Valve (C)
Automatically opens to relieve air pressure if supplied
pressure exceeds preset limit.
Air Filter (D)
Removes harmful dirt from compressed air supply.
311164M
Component Identification - Wall Mount
Air Regulator Adjustment (F)
Adjusts air pressure to the motor and fluid outlet pres-
sure of pump. Locate it close to the pump. Read air
pressure on gauge (E).
* Fluid Drain/Purge Valve (J)
Open valve to relieve pressure and when flushing or
priming pump. Close valve when spraying.
De-Ice Control (T)
Turn knob (open) to reduce icing.
* Required system components.