System Components
* Bleed Type Master Air Valve (B)
Trapped air can cause the pump to cycle unexpectedly,
which could result in serious injury from splashing or
moving parts.
•
Be sure the valve is easily accessible from the pump
and located downstream from the air regulator.
•
Required in your system to relieve air trapped
between it and the air motor when the valve is
closed.
•
Open to supply air to the motor.
•
Close to shut off air to the motor, and bleed any
trapped air from the motor.
* Air Pressure Relief Valve (C)
Automatically opens to relieve air pressure if supplied
pressure exceeds preset limit.
Air Filter (D)
Removes harmful dirt from compressed air supply.
311164M
Component Identification - Wall Mount
Air Regulator Adjustment (F)
Adjusts air pressure to the motor and fluid outlet pres-
sure of pump. Locate it close to the pump. Read air
pressure on gauge (E).
* Fluid Drain/Purge Valve (J)
Open valve to relieve pressure and when flushing or
priming pump. Close valve when spraying.
De-Ice Control (T)
Turn knob (open) to reduce icing.
* Required system components.
TI8160b
11