Datatrak Operation; Setup Mode; Run Mode - Graco xtreme Instruction Manual

Table of Contents

Advertisement

DataTrak Operation

DataTrak Operation
NOTE: To prevent damage to the DataTrak soft
key buttons, do not press the buttons with
sharp objects such as pens, plastic cards, or
fingernails.
NOTE: DataTrak is included with certain mod-
els. See Models, page 4, for a list of models fea-
turing DataTrak.
NOTE: The DataTrak display (Y) will turn off
after 1 minute to save battery life. Press any key
to wake up the display.

Setup Mode

1. See F
. 5. Press and hold
IG
Setup menu appears.
2. To enter settings for runaway, lower size, and flow
rate units, and to enable runaway, E1, E2, and E5
error options, press
to save the value and move the cursor to the
next data field.
NOTE: When runaway, E1, E2, and E5 error
options are enabled, a ✓ will appear on the
setup screen. See F
3. Move the cursor to the E5 error enable option field,
then press
once more to exit Setup mode.
20
for 5 seconds until
to change the value, then
. 5.
IG

Run Mode

Runaway
1. See F
. 5. If pump runaway occurs, the runaway
IG
solenoid will actuate, stopping the pump. The LED
(W) will flash and the display (Y) will indicate a run-
away condition (see Table 3).
2. To reset runaway monitor, close master air valve (B).
Wait for air to completely bleed off the air motor
before going to step 3. The screen will change to
indicate this, as shown below.
B
3. Press
to clear the diagnostic code and reset the
runaway solenoid.
4. Open master air valve (B) to restart pump.
NOTE: To disable runaway monitoring, go to
setup mode and set runaway value (T) to 0
(zero) or disable (RT)
(see F
. 5).
IG
311164M