Rinnai RHFE-308FTR How To Use Manual page 25

Hide thumbs Also See for RHFE-308FTR:
Table of Contents

Advertisement

x
Do not install the heater in an unusually dusty
area.
l
Use a flue guard if the terminal is easily
accessible to children.
l
Check local regulations.
l
Guards are available as an optional extra.
l
Floor must be level.
l
Do not use electrical extension cords to
connect the unit to a power supply.
l
Keep the power cord away from the flue.
FLUE MANIFOLD
POSITION
Important
The centre of the hole for the flue manifold
must
only
be
drilled
in
the
position
indicated on the diagram below.
Drill Hole
80mm
0 0
thru wall
Flue Elbow
110
110
,-y-l/
ii
ii
_.-.-.
_.-.-.
+--
+-- .-.-.-!
.-.-.-!
I I
I I
j j
2 2
1 I
1 I
I I
I I
l l -
l l -
I I
t t
' '
213
213
cl
cl
All measurements
are taken from
the extremities
of the appliance.
Before drilling the flue hole, check for water and
gas pipes as well as electrical cables.
For weatherboard
walls drill through
centre
of the weatherboard
from the outside,
then
drill from inside through the plaster board.
WALL MOUNTING
BRACKETS
0
Place top back spacer.
0
Mark the position of the top edge of the top
spacer on the wall.
0
Move the heater away from the wall.
0
Mark the centre lines 30 mm down from the
top edge mark, and 40 mm in from the left
and right hand sides of the top spacer.
0
Attach wall brackets at the marked position.
Remove right hand back spacer.
- 24 -