(3) Detaching and refitting the power supply PWB

<Procedure>
1. Remove the rear cover (See page 1-6-5).
2. Remove seven connectors and two tubs.
3. Remove the four screws and then remove
the power supply unit.
Power supply unit
Connector
Tub (white)
Connector
Figure 1-6-42
Screws
Screws
Figure 1-6-43
Connectors
Connectors
Tub (red)
Connector
Power supply unit