Siemens COMBIMASTER Reference Manual page 43

Hide thumbs Also See for COMBIMASTER:
Table of Contents

Advertisement

The user is offered a text-driven format for
commissioning, parameterising, configuring and
operating the inverter. The following features are
included:
• Illuminated high resolution LCD screen
with adjustable contrast.
• 7 languages.
• Central device for up to 31 inverters which
are networked together via USS.
• Up to 10 parameter sets can be stored in
non-volatile memory for uploading and
downloading between the clear text
operator panel and the drive.
• Help texts for diagnosing faults.
• Isolated RS232 interface for connecting to
a PC.
Dimensions H x W x D
Current drain at 5 V
Degree of protection
Maximum cable length
Table 1: Technical Data
JOG
1
Button
RUN / STOP
2
Inducator
RUN
RUN
3
Button
STOP
4
Button
MENU
Button
5
Indications as to which keys to use are shown in
the right hand column of the screen.
42
130 mm x 73 mm x 40 mm
250 mA
IP 54
5m
P000 RUNNING →
RPM=1250
FORWARD / REVERSE
F=50.00Hz
I=1.5A M=125% P
STOP
Jog
DOWN / DECREASE
P
Menu
Parameterisation
COMBIMASTER & MICROMASTER Integrated
All the main functions are accessible from the
main menu screen:
Operating display
Diagnosis of
drive faults
OPERATE
DIAG.
Parameterise
PARAMS
drive
MODE
Mode selection for module:
Local, Master, Internal, RS232-RS485 convert
Pressing the Menu and " keys simultaneously
causes a help screen, displaying the key features
of the Clear Text display module, to appear.
On power-up, unless configured otherwise, the
panel will show the Operating Display.
Drive status:
Stopped, Running,
Fault, Warning
STOPPED
P000
Motor
I=0.0A
current
Operating Display when in Local mode.
Drives present on the USS Bus
in this case 0, 7 and 16, selectable
LCD
with arrow keys
Display
Button
6
UP / INCREASE
RUNNING
7
Frequency
F=50.00Hz
8
Frequency
Drive status:
Stopped, Running,
Fault, Warning
Operating Display when in Master mode.
9
Button
The status LED indicates whether the drive is
running. When the LED is green, the drive is
running and when it is red the drive is stopped.
When accessing drive parameters, help texts are
associated with the parameter and the parameter
values.
Shows that internally
stored parameter set
is being accessed
Parameter
number
Text describing
selected parameter
Indicates that higher and lower
parameter values are available
Siemens plc. 1999
©
REFERENCE MANUAL
Upread parameter sets
from drive to module
Download parameter sets
from module to drive
UPREAD
M
DOWNLOAD
Language selection
LANGUAGE
P
Configure module features:
CONFIG.
Backlight, Contrast, Large
Numbers, Cursor, Help, Reset
Main Menu Screen
Output frequency
Direction of
(alternating with setpoint
motor rotation
when drive stopped)
M
Actual motor speed
S=50.00Hz
RPM=0
P
Motor voltage
V=0.0V
Enable broadcast function
to start and stop all drives
on bus
M
B
P
Output frequency
Direction of
(alternating with setpoint
motor rotation
when drive stopped)
Parameter group:
Parameter
All, General, Motor Plate,
access
Ramping, PID, Setpoint, Freq.
I/O, Comms. User Interface,
Setup, Changed from default
I PARAMS
All
M
P051=1
M
SELECT DIG I/P 1
P
run right
h
Text describing
selected value