Adjusting The Timing Relation Between The Looper And Needle Bar - JUKI MF-7800D Series Engineer's Manual

Table of Contents

Advertisement

(7) Adjusting the timing relation between the looper and needle bar

Standard Adjustment
1. Timing relation between the looper and the needle bar (synchronization)
It is the standard that dimension
is the same as dimension
when the needle bar goes up from the
A
B
lower dead point, the blade point of looper passes the rear of needle, and the left end of right needle aligns
with the blade point of looper, and when the needle bar comes down from the upper dead point, the blade
point of looper passes the front of needle, and the right end of right needle aligns with the blade point of
looper.
(Looper timing is more advanced by a piece of needle than the needle bar timing.)
Going of looper
Returning of looper
A
B
– 20 –

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents