6. OTHER CAUTIONS

(1) MF-7800D dry section

Dry section within the front area
Wet section in the feed mechanism

(2) Application of appropriate grease

1. Where lubrication is needed in any parts other than the lubricating sections, the appropriate grease (Juki Grease
A; 23640204, Juki Grease B; 40013640) is already applied. Never use any other type of grease.
2. In ordinary usage, the replenishment of grease is not required. In the case of rigorous usage, however, periodic
replenishment (once every one or two years) of the appropriate grease may be effective.
A
: Juki Grease A
B
: Juki Grease B
Wet section in the forced lubrication chamber
Wet section in the forced lubrication chamber
– 140 –