Connection With The Remote (External) Switches - Panasonic WJ-FS316 Operating Instructions Manual

Video multiplexer
Table of Contents

Advertisement

Connection with the Remote (External) Switches

The Video Multiplexer can be remote controlled if external switches (locally procured) are connected to the ALARM/REMOTE
connector. Remote switches, except SEQUENCE, are grouped under Remote SW1 and SW2. For more information refer to the
pin assignment tables on page 27.
Remote SW1
Notes:
• Switch 10 through 16 are applicable only to WJ-FS316/FS416.
• Make sure that the Function switch 1 is grounded and Function switch 2 is open.
Remote SW2
Note: Make sure that Function switch 1 and 2 are grounded.
29
Function 2
Function 1
Open
GND
or +5V
22
5
16
15
Function 2
Function 1
GND
GND
22
5
14 13 12 11 10 9
8
7
6
5
Camera Selection
5
GND
GND
Switch
4
3
2
1
GND
GND
GND
Switch
4
3
2
1
GND

Hide quick links: