Furuno CH-250 Installation Manual page 69

Hide thumbs Also See for CH-250:
Table of Contents

Advertisement

7.
Use a hair dryer or the like to dry the mounting hole, then apply the adhesive to the con-
tact areas between the retraction tank and mounting hole.
Apply the adhesive both to the retraction tank and mounting hole.
8.
Set the retraction tank to the tank reinforcement structure and mounting hole to align the
line marked at step 4.
After setting the retraction tank, remove the adhesive run over the mounting hole.
Reinforcement block
Hull plate
Flow rectification component
Fairing or stainless plate)
9.
Fasten the retraction tank to the tank reinforcement structure with eight hex. bolts
(M12).
Detailed view
Washer
Flange
Tank reinforcement structure
Tank reinforcement structure
Hex. nut
10. Confirm that the flange of the retraction tank is parallel with the waterline.
Hex. bolt
Washer
Washer
Washer
Hex. nut
AP-13
Retraction tank
Retraction tank
(PVC pipe)
(PVC pipe)
: Adhesive application area
Hex. bolt (M12)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ch-250s

Table of Contents