Power Specifications; Avaya Ethernet Routing Switch 4826Gts, 4826Gts-Pwr+, 4850Gts, And 4850Gts-Pwr - Avaya 4826GTS Installing Manual

Ethernet routing switch 4800 series
Hide thumbs Also See for 4826GTS:
Table of Contents

Advertisement

Installing the Avaya Ethernet Routing Switch
Warning the switch/stack will be reset to factory default
configuration. Do you wish to continue (y/n) ?
2. Enter y to restore the switch to default.
Important:
If you enter restore factory-default [-y], the[-y] parameter instructs the
switch not to prompt for confirmation.
The restore factory-default command is in the privileged exec command mode.

Power specifications

This section describes power specifications for the switches.
Avaya Ethernet Routing Switch 4826GTS, 4826GTS-PWR+,
4850GTS, and 4850GTS-PWR+
The following table describes the regulatory AC power specifications for the ERS 4826GTS,
4826GTS–PWR+, 4850GTS, and 4850GTS-PWR+ switches. It must be noted that regulatory power
specifications are based on the maximum rated capacity of the power supplies and are not based on
typical power consumption which is typically lower.
Table 6: AC power specifications
Input Current:
Input Voltage
(rms):
Power
Consumption:
Thermal Rating:
Inrush Current:
Turn on Condition: 1 second maximum
Important:
12 V output rise time, from 10 to 90 percent, must be the maximum of 50 ms and monotonic under all
defined input and output conditions.
Efficiency:
August 2016
4826GTS
4826GTS-PWR+
5A/2.5A
12A/6A
100 to 240VAC at 50
100 to 240VAC at
to 60 Hz
50 to 60 Hz
74.3W maximum
149W maximum
254 BTU/Hr maximum 508 BTU/Hr
maximum
40A maximum
70A maximum
1 second maximum
after application of AC
after application of
power
AC power
70 percent minimum
70 percent
minimum
Installing Avaya ERS 4800 Series
Comments on this document? infodev@avaya.com
4850GTS
4850GTS-PWR+
5A/2.5A
12A/6A
100 to 240VAC at
100 to 240VAC at
50 to 60 Hz
50 to 60 Hz
94.6W maximum
248W maximum
323 BTU/Hr
508 BTU/Hr
maximum
maximum
40A maximum
70A maximum
1 second maximum
1 second maximum
after application of
after application of
AC power
AC power
70 percent
70 percent
minimum
minimum
18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4826gts-pwr+4850gts4850gts-pwr+

Table of Contents