Safety Barrier (Ia/Ib) Dn ≤ 300; Safety Barrier (Ia) Dn ≥ 350; Cleaning Unit - Siemens MAG 1100 Handbook

Electromagnetic flowmeters
Table of Contents

Advertisement

SITRANS F M MAGFLO
2.5.3
Safety barrier (ia/ib)
DN ≤ ≤ ≤ ≤ ≤ 300
2.5.4
Safety barrier (ia)
DN ≥ ≥ ≥ ≥ ≥ 350
2.5.5

Cleaning unit

2. Technical data
Application
As combined unit with MAG 6000 only and MAG 1100 Ex/3100 Ex in the size
range DN 6-300
Ex approval
[EEx ia/ib] IIB
Cable parameter
Group
Electrode cable
IIB
Coil cable
IIB
During operation: −20 to +50°C
Ambient temperature
During storage: −20 to +70°C
19" insert
Enclosure material
Standard 19" insert in aluminium/steel (DIN 41494)
Width: 21 TE
Height: 3 HE
Enclosure rating
IP 20 to EN 60529 and DIN 40050
Mechanical load
1 G, 1-800 Hz sinusoidal in all directions to EN 60068-2-36
EMC performance
Emission
EN 50081-1 (Light industry)
Immunity
EN 50082-2 (Industry)
Application
For use with MAG 5000/6000 19 insert and MAG 3100 Ex in the size
range DN 350-2000
Ex approval
[EEx ia] IIC
Cable parameter
Group
IIC
IIB
IIA
During operation: −20 to +50°C
Ambient temperature
During storage: −20 to +70°C
19" insert
Enclosure material
Standard 19" insert in aluminium/steel (DIN 41494)
Width: 21 TE
Height: 3 HE
Enclosure rating
IP 20 to EN 60529 and DIN 40050
Mechanical load
1 G, 1-800 Hz sinusoidal in all directions to EN 60068-2-36
EMC performance
Emission
EN 50081-1 (Light industry)
Immunity
EN 50082-2 (Industry)
Application
For use together with MAG 5000 and 6000 19" insert to clean the electrodes
on MAG 1100, MAG 3100 or MAG 5100 W.
NB Must not be used with intrinsically safe systems
Cleaning voltage
(unloaded)
a.c. cleaning
60 V a.c.
d.c. cleaning
30 V d.c.
Cleaning period
60 sec. + 60 sec. pause period
Relay
Switch relay activated when cleaning is in progress
Load
42 V/2 A
Operation
Automatic
Yes
Manual
No
Indicator lamps
LEDs: "ON" and "CLEANING"
115-230 V a.c. +10% to −15%, 50-60 Hz, 7 VA cleaning, 5 VA stand by
Supply voltage and
power consumption
During operation: −20 to +50°C
Ambient temperature
During storage: −20 to +70°C
19" insert
Enclosure material
Standard 19" insert in aluminium/steel (DIN 41494)
Width: 21 TE
Height: 3 HE
Enclosure rating
IP 20 to EN 60529 and DIN 40050
Mechanical load
1 G, 1-800 Hz sinusoidal in all directions to EN 60068-2-36
DKFD.PS.027.W3.02
Safety barrier & cleaning unit
Capacity in µF
Inductance in mH
≤ 31
≤ 0.5
Capacity in µF
Inductance in mH
≤ 4.1
≤ 45
≤ 45
≤ 80
≤ 8
≤ 1.5
≤ 87
≤ 87
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mag 3100Mag 5100 wMag 5000Mag 6000

Table of Contents