Minimum Conductivity; Liner Selection Guide; Electrode Selection Guide; Installation Conditions - Siemens MAG 1100 Handbook

Electromagnetic flowmeters
Table of Contents

Advertisement

SITRANS F M MAGFLO
3.2.1

Minimum conductivity

3.2.2

Liner selection guide

3.2.3

Electrode selection guide

3.3

Installation conditions

20
3. Project guidance
Applications
Compact mounted
Remote mounted
With empty pipe detection
Ex-installations
(Remote mounted only)
District heating systems
(Without DC cleaning unit)
Liner
Ceramics Al
O
2
3
PFA
Neoprene
EPDM
PTFE
    
Linatex
Ebonite
Electrodes
AISI 316 Ti
AISI 316 Ti Ceramic coated
Hastelloy C-276
Titanium
Tantalum
Platinum and platinum/irridium
DKFD.PS.027.W3.02
Min. conductivity
5 µS/cm
5 µS/cm
20 µS/cm
30 µS/cm
250 µS/cm
Applications
General purpose, agressive chemicals
General purpose, dairy, food and beverage
General purpose, sewage
Drinking water, sea water
Agressive chemicals, paper and pulp, high temperature applica-
tions
Abrasive media and mining slurries
Drinking water
Applications
General purpose, water, sewage and district heating
High content of fibres, paper pulp
Good chemical proporties, sea water
Chlorine, chlorite, nitric and chromic acids
Textile bleaching industry
Almost any acid solution
The ultimate electrode material. Unaffected by most liquids
Reading and operating the flowmeter is possi-
ble under almost any installation conditions
because the display can be oriented in relation to
the sensor. To ensure optimum flow mea-
surement, attention should be paid to the fol-
lowing:

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mag 3100Mag 5100 wMag 5000Mag 6000

Table of Contents