Ricoh Aficio SP 100SF Service Manual page 193

Table of Contents

Advertisement

Training Retries
Encoding
Protocol Definition Timer
T0 Timer
T1 Timer
T4 Timer
RX Settings
Tone Sound Monitoring
Sets the number of training retries to be repeated before
automatic fallback takes effect.
• 1 Time. Reduce speed to next level after 2 PPR commands.
• 2 Times. (Default) Reduce speed to next level after 3 PPR
commands.
• 3 Times. Reduce speed to next level after 4 PPR commands.
• 4 Times. Reduce speed to next level after 2 PPR commands.
Selects data compression mode for TX/RX. The first selection is
the most complex, the third selection the least complex:
• MMR+MR+MH (Default)
• MR+MH
• MH
Timeout for the remote station to respond in automatic send
mode.
• Default: 55 sec.
• Range: 35 to 140 sec.
Sets the DIS waiting time.
• Default: 40 sec.
• Range: 30 or 40 sec.
Sets the time interval between command signal transmissions.
• Default: 3 sec.
• Range: 3 or 4.5 sec.
Determines when tones are monitored.
• No Monitoring
• Up to Phase B
• All TX Phases
Utilities
191

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aficio sp 100suAficio sp 100

Table of Contents