Transferring Of Parameters; Uploading Of Parameters; Downloading Of Parameters - ABB PST30 Installation And Commissioning Manual

Softstarters
Hide thumbs Also See for PST30:
Table of Contents

Advertisement

Chapter 5
Connection
Figure 39: Upload
Figure 40: Download
58

5:3.3 Transferring of parameters

To transfer(copy) parameters from one softstarter to another,
connect the keypad to the chosen softstarter and follow the
sequence below.

5:3.3.1 Uploading of parameters

Enter the menu Transfer par. Select To Keypad and confirm
by pressing Select. A text Load to keypad will be displayed.
Continue by pressing Execute and then Yes when the text
Are you sure is displayed. Transfer OK will now be displayed
if the transmission was successful, otherwise Transfer NOT
OK.

5:3.3.2 Downloading of parameters

To download the parameters, connect the keypad to the
chosen softstarter and select To Starter. A text Load to Start
will be displayed. Continue by pressing Execute and then
Yes when the text Are you sure is displayed. Transfer OK will
now be displayed if the transmission was successful,
otherwise Transfer NOT OK. Set the parameter Setting Ie
and confirm by pressing Next.
The parameters in the menu Service Settings will not be
transferred.
How to operate the keypad, see Chapter 6 "Human-Machine
Interface (HMI)".
1SFC132003M0201

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents