2.5 Utility
Note
For a list of common errors and solutions, see "4.1.5 Troubleshooting by Error Log" in the KX-
TDA600 Installation Manual", 4.1.5 Troubleshooting by Error Log" in the KX-TDA100/KX-TDA200
Installation Manual, or "4.1.5 Troubleshooting by Error Log" in the KX-TDA50 Installation Manual.
To view the error log
From the Utility menu, select Error Log.
2.5.9
Utility—T1 Signaling Bit Monitor (KX-TDA100/KX-TDA200/
KX-TDA600 only)
Displays reference signaling bit information for all channels of the T1 card, by monitoring sent and
received A, B, C and D bits. This utility is intended for use by dealers.
This option is only available at Installer level, and requires that the target T1 card be set to INS status.
While monitoring is being performed, any displayed bits whose value changes from 0 to 1 or vice
versa will be highlighted in red until the next screen refresh is performed.
To view signaling bit information
1.
From the Utility menu, select T1 Signaling Bit Monitor.
2.
From the Slot No drop-down list, select the target slot.
3.
From the Interval Timer drop-down list, select the number of seconds between each automatic
screen refresh.
4.
Click Start.
Monitoring will be performed and the screen will refresh according to the interval specified.
To refresh the screen manually at any time, click Refresh.
5.
Click Stop to end monitoring.
2.5.10 Utility—T1 Line Trace (KX-TDA100/KX-TDA200/KX-TDA600
only)
Traces the sent and received signaling bits and dial numbers on the specified channel of the T1 line.
This utility is intended for use by dealers.
This option is only available at Installer level, and requires that the target T1 card be set to INS status.
To view T1 trace data
1.
From the Utility menu, select T1 Line Trace.
2.
From the Slot No drop-down list, select the target slot.
3.
From the CH No drop-down list, select the target channel.
4.
Click Start.
Trace information will be displayed. The information is automatically updated whenever the data
being monitored changes.
5.
Click Stop to end the trace.
6.
Select an option:
Click Capture to save the displayed trace information.