LIGHTWEIGHT BLOCK-IN INSTALLATION (Cont.)
Place the Fireplace Xtrordinair on top of the block platform and position it to meet the finished
facing criteria (See illustration below). Level the fireplace front to back and side to side with
non-combustible shims. This will insure that the doors of the fireplace will not swing open or
closed when they are unlatched. Insert the chimney adapter into the fireplace (see the
"Chimney Adapter" section in the "Factory-Built Chimney" portion of the specifications). The
chimney adapter has spacers to keep the masonry from covering up the area between the
inner and outer liners. These spacers must not be covered during installation and air must
be allowed to reach the area between the inner and outer liners. The double-wall chimney
pipe is designed to have air flow through the outside portion of the pipe during operation.
This cools the chimney. Failure to allow air to reach the area between the inner and outer
liner of the double-wall chimney pipe may cause a fire hazard.