LIGHTWEIGHT BLOCK-IN SPECIFICATIONS (Continued)
Factory-Built Chimney (Continued)
Factory-Built Chimney Brands Approved for use:
Fireplace Xtrordinair is approved with the use of Temco 82 Series, Superior TF8, FMI 8HT,
Marco 8D series, and Majestic CF8 series chimneys (See the table below for part numbers).
All the components used in the chimney system must be from the same model
line and manufacturer or supplied by Travis Industries as a component for that
chimney system. The parts list below illustrates the number of chimney parts available for
each brand of chimney and their appropriate part number.
Chimney Components
12" Chimney Section
18" Chimney Section
24" Chimney Section
36" Chimney Section
48" Chimney Section
Offsets
Flashing
Chimney Cap
Flue Support
Firestop Spacer
Clearance to Combustibles:
All chimney systems must have a minimum of 2" clearance to combustible materials measured
horizontally.
Use offsets if necessary to maintain this clearance (see "Using Offsets" in this
section).
If the manufacturer specifies a larger clearance, use that clearance.
Firestops:
Every time the chimney penetrates a floor a
firestop is needed on the bottom side of the floor
joist. When passing through the attic the firestop
needs to be on the attic side of the joists (See the
illustration to the right). When the chimney passes
through a living space it must be totally enclosed
with a 2" minimum clearance to combustibles.
The space between frames that hold the firestop in
place should be measured as follows:
Temco
Superior
FMI
Marco
Majestic
Framing for Roof
When installing into a sloped roof, it is important to determine the size of the framing. The
table on the following page can be used to determine the size of the framing needed to install
the corresponding chimney pipe. The numbers on the left represents the pitch of the roof
(rise/run). The other columns give the size of the framing for 2 x 4 and 2 x 6 rafters. It may not
be necessary to frame around the hole opening if the hole is between the rafters and the
minimum clearance to combustibles can be maintained.
Chimney Parts List
Temco 82
8212D
8218D
8224D
8236D
8248D
8232E
8206F
8203D
8204S
---
16"
16 1/2"
16 1/2"
16 1/2"
17 1/2"
Superior TF8
FMI 8HT
TF8-12
12-8DM
TF8-18
18-8DM
---
TF8-36
36-8DM
TF8-48
48-8DM
TF8-30, TF8-E30
30E-8D
8-F6
12F8
TF8-CTO
RTL-8D
8-54
125-8D
8FS-2
FS-8D
Space
between
frames
Page 21
Marco 8D
12 - 8D
18 - 8D
----
----
36 - 8D
48 - 8D
30E - 8D
12F - 8D
BT - 8D
12CPS - 8D
FS30 - 8D
M a j e s t i c
C F 8
CF81
CF818
----
CF83
CF84
CF830 A/2
8-6-12
CFC8-36
TCS8A
FS2A
Firestop