Exhaust Direction; Exhaust System; Position And Level The Unit - Speed Queen ATGE9AGPWH Installation Instructions Manual

Table of Contents

Advertisement

Installation
Exhausting dryer in hard-to-reach locations can be done by
installing 521P3 Flexible Metal Vent Kit (available as option-
al equipment at extra cost).
Sufficient make-up air must be supplied to replace the air ex-
hausted by the dryer. The free area of any opening for outside
air must be at least 40 in.
Failure to exhaust dryer properly will void warranty.
NOTE: Venting materials are not supplied with the dry-
er (obtain locally).
IMPORTANT: DO NOT block the airflow at the bottom
of the dryer's front panel with laundry, rugs, etc. Block-
age will decrease airflow through the dryer, thus reduc-
ing the efficiency of the dryer.

Exhaust Direction

The dryer can be exhausted to the outdoors through the back, left,
right or bottom of the dryer. EXCEPTION: Gas dryers cannot be
vented out the left side because of the burner housing.
Number of 90° Elbows
Maximum length of 4 in. [102 mm] diameter rigid metal duct.
0
1
2
3
4
NOTE: Deduct 6 feet [1.8 m] for each additional elbow.
NOTE: The maximum length of a 4 in. [102 mm] diame-
ter flexible metal duct must not exceed 7.87 ft. [2.4 m],
as required to meet UL2158, clause 7.3.2.A.

Position and Level the Unit

20
2
2
[1016 mm
].
Recommended
1
1. 4 in. [102 mm]
65 feet [19.8 m]
55 feet [16.8 m]
47 feet [14.3 m]
36 feet [11.0 m]
28 feet [8.5 m]
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
Dryer is shipped from factory ready for rear exhaust.
Exhausting the dryer through sides or bottom can be accomplish-
ed by installing a Directional Exhaust Kit, 528P3, available as
optional equipment at extra cost.

Exhaust System

For best drying results, recommended maximum length of ex-
haust system is shown in Table 4 .
To prevent backdraft when dryer is not in operation, outer end of
exhaust pipe must have a weather hood with hinged dampers (ob-
tain locally).
NOTE: Weather hood should be installed at least 12 in-
ches [305 mm] above the ground. Larger clearances
may be necessary for installations where heavy snow-
fall can occur.
Weather Hood Type
Use Only for Short Run Installations
1
D673I_SVG
1
1. 2.5 in. [64 mm]
55 feet [16.8 m]
47 feet [14.3 m]
41 feet [12.5 m]
30 feet [9.1 m]
22 feet [6.7 m]
Table 4
D802I_SVG
Part No. 804671R2