Installation
color-coded hose from the hot water faucet goes to the water
mixing valve marked "H" and the blue color-coded hose from
the cold faucet goes to the valve marked "C". Refer to Figure
Figure 6 .
6. Then, using a pliers, screw approximately 1/4 turn.
IMPORTANT: DO NOT cross thread or overtighten
couplings. This will cause them to leak.
7. Turn water on and check for leaks.
8. If leaks are found, turn off the water, unscrew hoses and rein-
stall them until there are no leaks.
IMPORTANT: Turn off water supply whenever there
will be an extended period of non-use.
1
COLD
HOT
8
7
1. Filter Screen (Screen must be facing outward)
2. Fill Hose
3. Rubber Washer (Plain)
4. Cold Water Connection
5. Hot Water Connection
6. Install this end of hose to valve connections at rear of
washer.
7. Install this end of hose to water supply faucet.
8. Faucet
Figure 6
IMPORTANT:
Hoses and other natural rubber parts deteriorate after extended
use. Hoses may develop cracks, blisters or material wear from the
temperature and constant high pressure they are subjected to.
All hoses should be checked on a monthly basis for any visible
signs of deterioration. Any hose showing the signs of deteriora-
tion listed above should be replaced immediately. All hoses
should be replaced every five years.

Risers

Risers (or air cushions) may have to be installed if the pipes
knock or pound when flow of water stops. The risers are more ef-
ficient when installed as close as possible to the water supply fau-
cets. Refer to Figure 7 .
12
4
3
2
5
6
FLW2304N_SVG1
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
2
1. Risers (Air cushions)
2. Water Supply Faucets
Figure 7
Connect Drain Hose to Drain Recepta-
cle
Remove the drain hose from its shipping position on the rear of
the washer by unhooking the hose from the retainer clamp and by
removing the shipping tape.
Install the drain hose into the drain receptacle (standpipe, wall or
laundry tub) following the instructions below.
IMPORTANT: Drain receptacle must be capable of han-
dling a minimum of 1-1/4 inch [32 mm] outside diame-
ter drain hose.
Drain Flow Rate
Drain Height
3 ft. [0.9 m]
5 ft. [1.5 m]
6 ft. [1.8 m]
7 ft. [2.1 m]
8 ft. [2.4 m]

Standpipe Installation

1. Place the drain hose into the standpipe.
1
W005I_SVG
Flow Rate
gallons per minute [lit-
ers per minute]
8.19 [31]
7.27 [27.5]
6.31 [23.9]
4.89 [18.5]
2.79 [10.6]
Part No. 804671R2