Advertisement

3. Use a strain relief and insert end of power cord through power
supply hole.
4. Use the three screws from the accessories bag to attach the
power cord wires to the terminal block. Refer to Figure 15 .
3-Wire Connection
1
4
1. "L1" Terminal
2. Neutral Terminal
3. "L2" Terminal
4. Earth/Ground to Bulkhead
5. Using a screwdriver, tighten all screws firmly.
IMPORTANT: Failure to tighten these screws firmly
may result in wire failure at the terminal block.
6. Secure the strain relief to the power cord, or wires, where they
enter the dryer cabinet.
7. Check the continuity of the earth/ground connection before
plugging the cord into an outlet. Use an acceptable indicating
device connected to the center earth/ground pin of the plug
and the green screw on the back of the cabinet.
8. Reinstall access cover and screw.

Connecting Power Cord with Four-Wire Plug

NOTE: Four-wire cord is required for new branch-cir-
cuit installations, mobile homes or where codes do not
permit grounding through neutral.
Part No. 804671R2
D696I_SVG
Figure 14
2
3
DRY2508N_SVG
Figure 15
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
1
6
1. Typical Four-Wire Receptacle
2. Power Cord – Not Supplied with Dryer
3. Strain Relief Nut
4. Strain Relief
5. 0 V.A.C.
6. 240 ± 12 V.A.C.
7. 120 ± 12 V.A.C.
Figure 16
1. Disconnect power to dryer.
2. Remove access cover from rear of dryer.
3. Remove earth/ground screw from earth/ground to neutral wire
and save for use in Step 5. Earth/ground to neutral wire will
be attached to the neutral terminal in Step 6.
Installation
2
3
4
5
DRY2016N_SVG
DRY2467N_SVG
Figure 17