Path Status
Response error
Cannot detect port
180
Notes on connecting external arrays
Examples of Recovery
Procedure
copy program. If the volume is set
as a pair volume, the volume might
be protected because of the pair
status. If the volume is protected,
change the pair status or delete the
pair.
LUN Security XP Extension might
have changed the volume's access
attribute.
Check the volume's access
attribute. If the volume is protected
by the access attribute, release the
protection.
The volume might have been set as
a pair volume for data copy.
Check if the volume is set as a pair
volume of Business Copy XP,
Continuous Access XP, Continuous
Access XP Journal, or some other
copy program. If the volume is set
as a pair volume, the volume might
be protected because of the pair
status. If the volume is protected,
change the pair status or delete the
pair.
LUN Security XP Extension might
have changed the volume's access
attribute.
Check the volume's access
attribute. If the volume is protected
by the access attribute, release the
protection.
There is a problem with connection
to the external array. The following
are possible causes:
The fibre cable is not physically
connected properly.
The topology setting does not
match between the external and
target ports.
If the external array is
connected through switches, the
switches' settings might not be
appropriate.
Check if the fibre cable is
connected properly, and then set
the Fibre Channel port properly
using LUN Manager.