HP StorageWorks XP12000 User Manual page 158

External storage xp
Hide thumbs Also See for StorageWorks XP12000:
Table of Contents

Advertisement

Error
158
Troubleshooting External Storage XP
Corrective action
Internal error
Timeout
Target error
The topology setting
between the external
and target ports does
not match.
Because security is set
on the port, the
external array's
device cannot be
recognized from the
local array.
If the external array is
connected through
switches, the switches'
settings might not be
appropriate.
Corrective action: Check
the condition of the
connection to the external
array. If you cannot
restore the path, contact
your HP account support
representative.
Status: A program error
occurred, or there is a
logical contradiction.
Corrective action: Contact
your HP account support
representative.
Status: Processing was
retried because an
abnormal reply
(Response) was returned,
but processing has
stopped due to a timeout.
Corrective action: The
external array's port of is
recognized. Check the
condition of the
connection (for example,
cables and switches) to
the external array. If you
cannot restore the path,
contact your HP account
support representative.
Status: An error, such as
blockade of the controller,
was found in the external
array's port.
Corrective action: Check
the status of the external
array's ports. If you