Error
External Storage XP user guide for the XP12000, XP10000, SVS200
Corrective action
LDEV size reduced
Not ready
Illegal request
deleted, or the external
array itself was replaced
by another device.
Corrective action: The
external array's port is
recognized. See the
internal array's
documentation, and
check if the operation that
changes the mapped
device's setting
information has not been
performed.
Status: The external
array's volume capacity
setting changed (was
reduced).
Corrective action: Check
the volume capacity of the
external array's LU.
Execute the Delete LU
operation, and retry the
Add LU operation.
Status: The reply from the
external array was
NOTREADY. The external
array's drive is spinning
up, or the external array's
device is being formatted.
Corrective action: The
path cannot be used to
access the external array.
Check the external array's
status. If you cannot
restore the path, contact
your HP account support
representative.
Status: The reply from the
external array was
ILLEGALREQUEST. The
command cannot be
executed to the external
array's device. Data
protection might be set on
the external array's
device.
Corrective action: The
external array's port is
recognized. Check the
external array's setting. If
you cannot restore the