Troubleshooting the EDA
Table 5-1
Problem
EDA does not turn on.
Rechargeable
lithium-ion battery did
not charge.
Cannot see characters
on display.
During data
communication, no
data transmitted, or
transmitted data was
incomplete.
No sound.
Cause
Lithium-ion battery
Charge or replace the lithium-ion battery in the EDA.
not charged.
Lithium-ion battery
Install the battery properly. See
not installed properly.
Main Battery on page
System crash.
Perform a warm boot. If the EDA still does not turn on,
perform a cold boot. See
Battery failed.
Replace battery. If the EDA still does not operate, perform
a warm boot, then a cold boot. See
page
EDA removed from
Insert EDA in cradle. The standard capacity battery (1900
cradle while battery
mAh) fully charges in less than four hours. The extended
was charging.
capacity battery (3800 mAh) fully charges in less than eight
hours.
EDA not powered on. Press the Power button.
EDA removed from
Replace the EDA in the cradle, or reattach the
cradle or
communication cable and re-transmit.
disconnected from
host computer during
communication.
Incorrect cable
See the system administrator.
configuration.
Communication
Perform setup. Refer to the MC70 Integrator Guide for
software was
details.
incorrectly installed
or configured.
Volume setting is low
Adjust the volume. See
or turned off.
Solution