Vehicle Cradle - Motorola MC7090CN User Manual

Enterprise digital assistant
Table of Contents

Advertisement

5 - 8
MC7090CN User Guide
Troubleshooting the Four Slot Ethernet Cradle (Continued)
Table 5-4
Symptom
Battery is not
charging.

Vehicle Cradle

Troubleshooting the Vehicle Cradle
Table 5-5
Symptom
EDA battery
charging LED does
not light up.
EDA battery is not
recharging.
No data transmitted,
or transmitted data
was incomplete.
Cause
EDA removed from
Replace the EDA in the cradle. The standard capacity battery
the cradle too soon.
(1900 mAh) fully charges in less than four hours. The
extended capacity battery (3800 mAh) fully charges in less
than eight hours. Tap Start - Settings - System - Power to view
battery status.
Battery is faulty.
Verify that other batteries charge properly. If so, replace the
faulty battery.
EDA is not inserted
Remove the EDA and reinsert it correctly. Verify charging is
correctly in the
active. Tap Start - Settings - System - Power to view battery
cradle.
status.
Ambient
Move the cradle to an area where the ambient temperature is
temperature of the
between 0
cradle is too warm.
Possible Cause
Cradle is not receiving
power.
EDA was removed from
the cradle too soon.
Battery is faulty.
EDA is not placed
correctly in the cradle.
Ambient temperature of
the cradle is too warm.
EDA removed from
cradle during
communication.
No null modem cable
was used.
Incorrect cable
configuration.
Cable missing or
disconnected.
Solution
o
o
C and 35
C.
Action
Ensure the power input cable is securely connected to the
cradle's power port.
Replace the EDA in the cradle. The standard capacity
battery (1900 mAh) fully charges in less than four hours.
The extended capacity battery (3800 mAh) fully charges in
less than eight hours.
Replace the battery.
Remove the EDA from the cradle, and re-insert correctly. If
the battery still does not charge, contact customer support.
The EDA battery charging LED slowly blinks amber when
the EDA is correctly inserted and charging.
Move to an area where the ambient temperature is between
o
o
0
C and 35
C.
Replace EDA in cradle and retransmit.
Some external devices require a null modem cable.
Retransmit using a null modem cable.
See the system administrator.
Re-connect cable.

Advertisement

Table of Contents
loading