Four Slot Ethernet Cradle

Troubleshooting the Four Slot Ethernet Cradle
Table 5-4
Symptom
Attempt by the EDA
to ActiveSync failed.
During
communication, no
data transmits, or
transmitted data was
incomplete.
Cause
EDA removed from
Wait one minute and reinsert the EDA in the cradle. This
the cradle while the
allows the cradle to attempt another synchronization.
LED was blinking
green.
Using an outdated
Visit
version of
software.
ActiveSync.
ActiveSync on the
Wait one minute and reinsert the EDA in the cradle. This
host computer has
allows the cradle to attempt another synchronization.
not yet closed the
previous ActiveSync
session.
Incorrect cable
Ensure the correct cable (Ethernet) is used with the cradle.
configuration.
Communication
Perform setup as described in the MC70 Integrator Guide.
software improperly
configured.
EDA ActiveSync
On the EDA, tap Start - ActiveSync - Tools - Options - Options
disabled or not
button. Then, uncheck the Enable PC sync using this
configured to accept
connection: check box.
network connection.
Host ActiveSync
On the host computer, check File - Connection Settings - Allow
disabled or not
network (Ethernet) Server Connection with this desktop
configured to accept
computer.
network connection.
EDA removed from
Replace EDA in cradle and retransmit.
cradle during
communications.
EDA has no active
An icon is visible in the status bar if a connection is currently
connection.
active.
Maintenance & Troubleshooting
Solution
http://www.microsoft.com
for the latest ActiveSync
5 - 7