Using the Fuel Shut-off Valve

Close the fuel shut-off valve for transport, maintenance, and
storage
(Figure
15).
Ensure the fuel shut-off valve is open when starting the
engine.
1
2
G008948
1. On position
Starting and Stopping the
Engine
Starting the Engine
1. Connect the wires to the spark plugs.
2. Open the fuel valve.
3. Move the right motion-control lever to neutral locked
position.
4. Set the parking brake; refer to
Brake (page
18).
5. Move the blade-control switch (PTO) to the Off
position.
6. Move the throttle lever midway between the Slow and
Fast positions.
Note: A warm or hot engine may not require choking.
g015365
Figure 15
2. Off position
Setting the Parking
7. Turn the ignition key to the Start position
When the engines starts, release the key.
Important: Do not engage the starter for more
than 5 seconds at a time. If the engine fails to
start, allow a 15 second cool-down period between
attempts. Failure to follow these instructions can
burn out the starter motor.
Note: Additional starting cycles may be required
when starting the engine for the first time after the fuel
system has been without fuel completely.
1. Off position
2. Run position
20
Figure 16
(Figure
G008947
Figure 17
3. Start position
17).