Command Format - Hitachi CP-WU13K User Manual

Hide thumbs Also See for CP-WU13K:
Table of Contents

Advertisement

1. Protocol
19200bps,8N1

2. Command format

("h" shows hexadecimal)
Byte Number
Command
Action
<SET>Change setting to
desired value [(cL)(cH)]
by [(bL)(bH)].
<GET>Read projector
internal setup value [(bL)
(bH)] .
<INCREMENT>
Increment setup value
[(bL)(bH)] by 1.
<DECREMENT>
Decrement setup value
[(bL)(bH)] by 1.
<EXECUTE> Run a
command [(bL)(bH)].
[Header code] [Packet] [Data size]
Set [BEh, EFh, 03h, 06h, 00h] to byte number 0~4.
[CRC flag]
For byte number 5, 6, refer to RS-232 Communication command table.
[Action]
Set functional code to byte number 7, 8.
<SET> = [01h, 00h], <GET> = [02h, 00h], <INCREMENT> =[04h, 00h]
<DECREMENT> = [05h, 00h], <EXECUTE> = [06h, 00h]
Refer to RS232 Communication command table
[Type] [Setting code]
For byte number 9~12 , , refer to RS-232 Communication command table.
0
1
2
3
Header
Header
Data
code
size
Packet
L
H
L
BEh EFh
03h
06h 00h
Communication settings
4
5
6
7
8
CRC
Action
flag
H
L
H
L
H
(aL) (aH) 01h 00h (bL) (bH) (cL) (cH)
(aL) (aH) 02h 00h (bL) (bH) 00h 00h
(aL) (aH) 04h 00h (bL) (bH) 00h 00h
(aL) (aH) 05h 00h (bL) (bH) 00h 00h
(aL) (aH) 06h 00h (bL) (bH) 00h 00h
9
10
11
12
Data
Setting
Type
code
L
H
L
H
65

Advertisement

Table of Contents
loading

Table of Contents