16.10 COMPRESSOR FAULTS

Compressor runs
continuously
Refer to Section

16.11 COMPRESSOR RUNS CONTINUOUSLY

Refer to Section
0
Compressor will
not run and is cold
.
to touch
Refer to Section
0
Are there any
faults on the
LCD display?
Yes
Is
refrigeration
taking place?
Yes
Are the FC/PC
reaching set
No
temperatures?
No
Check for loss of
gas (leak) or
blockage.
Compressor will
not run and is hot
.
to touch.
Refer to Section
0
Continue testing.
No
Check for loss of
gas (leak) or
No
blockage.
Check for correct fitting of
sensors. Check sensor
Yes
resistances.
84
0