321023
8.1.4.3
Service Test 102 - Compressor/Condenser System.
When selected and activated, this test will operate the compressor/condenser fan circuit. A service
technician should evaluate proper operation of the compressor and condenser fan. The Refrigerator
Temperature Up/Down keypads
"Off".
8.1.4.4
Service Test 112 - Freezer Fan Operation.
When selected and activated, this test will operate the freezer fan (evaporator fan). The Refrigerator
Temperature Up /Down keypads
technician will have to inspect the fan for proper function.
• The refrigerator display will show the voltage level supplied to the fan. When on, the refrigerator
display will show a voltage reading between 11.0 to 14.0 volts. When off, the refrigerator display
will show a voltage reading of 0.0 volts.
DEFROST THERMOSTAT OPEN
DEFROST THERMOSTAT CLOSED
/
OBSERVE COMPRESSOR & CONDENSER FAN FUNCTION
/
EVAPORATOR FAN IS OFF
EVAPORATOR FAN IS ON
will toggle the compressor drive circuit between "On" and
will toggle the fan drive circuit between on and off. The
38