Fisher & Paykel RF201A Service Manual page 42

Table of Contents

Advertisement

819091D
Input/Output Status
Press the UP key once more – Input/Output status.
IO shown indicates the product is in input/output status.
The LCDs that are highlighted indicate what
components are on.
Note: When the PC door is opened, the backlight will turn off. The LCD for the FC or PC door will come on
when either door is opened.
The IO shown stands for Input/Output, not a temperature.
Diagram D
Input/Output Status
PC2 Sensor Temperature
Press the UP key once more – PC2 sensor. This sensor is attached to the water tank.
0
Note: 5.0 shown indicates the temperature of the PC2 sensor is 5
C (41° F).
Diagram E
PC Sensor 2
PC2 Sensor Temperature
Press the UP key once more – Icemaker sensor.
0
Note: 12.0 min shown indicates the temperature of the Icemaker sensor is -12
C (10.4° F).
Diagram F
Icemaker Sensor
Fault History
Press the UP key once more – Fault History.
HOO will be showing.
Diagram G
Fault History
To exit the diagnostic mode, press the MENU key. If not terminated manually, the diagnostic mode will time
out and go back to default display after 5 minutes.
Note: The door alarms do not operate when the appliance is in diagnostic mode.
42