DCR-PC115/PC115E/PC120BT/PC120E
3-1-2.

Precautions on Adjusting

1) The adjustments of this unit are performed in the VTR mode
or camera mode.
To set to the VTR mode, set the power switch to "VCR" (or
"PLAYER") or set the "Forced VTR Power ON mode" using
the adjustment remote commander (Note 1).
To set to the Camera mode, set the power switch to "CAMERA"
or set the "Forced Camera Power ON mode" using the
adjustment remote commander (Note 2).
After completing adjustments, be sure to exit the "Forced VTR
Power ON Mode" or "Forced Camera Power ON Mode". (Note 3)
2) As removing the cabinet (L) assembly (removing CN2006 of
the VM-027 board) means removing the lithium 3V power
supply (BT001 on the FK1850 block), data such as date, time,
user-set menus will be lost. After completing adjustments, reset
these data. If the cabinet (L) assembly has been removed, the
self-diagnosis data, data on history of use (total drum rotation
time etc.) will be lost. Before removing, note down the self-
diagnosis data (data of page: 2, address: B0 to C6) and the data
on history use (data of page: 2, address: A2 to AA). (Refer to
"5-4.Service Mode" for the data on the history use and the
self-diagnosis data.)
3) The cabinet (L) assembly (control switch block (FK1850),
control switch block (PS1850), KY-060 board) needs not be
connected to operate the VTR block, if the "Forced VTR power
ON" mode is set. But, the monitor TV can't be connected
because the AUDIO/VIDEO jack is attached to the cabinet (L)
assembly. To remove the cabinet (L) assembly, disconnect the
following connectors.
VM-027 board CN2006 (51P, 0.3mm)
4) Short-circuit between TP001 of the flash unit (MC1850) and
the GND with the short jig about 10 seconds and discharge the
flashlight power supply capacitor. (Refer to "SERVICE
NOTE".) The flash unit (ST1850) needs not to be connected
during the adjustments. To disconnect it, disconnect the
following connector
Flash unit (MC1850) CN2003 (33P, 0.3mm)
5) To remove the cabinet (R) assembly, disconnect the following
connectors.
1. VM-027 board CN2005 (27P, 0.3mm) (Intelligent
accessory shoe)
2. VM-027 board CN2004 (5P, 0.5mm) (Microphone)
3. BT-003 board CN102 (Bluetooth antenna) *1
4. VC-270 board CN001 (15P, 0.3mm) (Memory stick
connector, control switch block (ME))
5. VC-270 board CN011 (88P, 0.4mm) (DC IN jack, battery
terminal, LCD block)
6) As the DC IN jack and LANC jack are connected to the FJ-
035 board of the cabinet (R), the FJ-035 board must be
connected to the VC-270 board. So remove the FJ-035 board
and DC IN jack from the cabinet (R). To remove them from
the cabinet (R), disconnect the following connectors. (The LCD
block and battery terminal need not to be connected.)
1. FJ-035 board CN1336 (16P, 0.8mm) (LCD block)
2. FJ-035 board CN1333 (6P, 0.5mm) (PANEL OPEN/
CLOSE switch, PANEL REVERSE switch)
3. FJ-035 board CN1334 (3P, 1.5mm) (Battery terminal)
Connect the FJ-035 board to the following connector of VC-
270 board.
VC-270 board CN011 (88P, 0.4mm)
7) There is a danger of electric shock when the flash unit
(MC1850) is handled by hand. The flash unit (MC1850) needs
not to be connected during the adjustments. To disconnect it,
disconnect the following connector after short circuit between
TP001 of the flash unit (MC1850) and the GND with the short
jig about 10 seconds and discharge the flashlight power supply
capacitor. (Refer to "SERVICE NOTE".)
VC-270 board CN009 (27P, 0.3mm)
8) The Lens block needs not to be connected. To remove it,
disconnect the following connector.
VC-270 board CN302 (72P, 0.4mm)
9) FP-386 flexible (Remote commander receiver ,Night shot LED)
needs not to be connected. To remove it, disconnect the
following connector.
VC-270 board CN002 (6P, 0.4mm)
10) BT-003 board (Bluetooth circuit *1) needs not to be connected.
To remove it, disconnect the following connector.
VC-270 board CN010 (15P, 0.3mm) *1
11) The VM-027 board (Viewfinder, microphone amplifier) needs
not be connected to operate the VTR block, if the "Forced VTR
power ON" mode is set. But, the monitor TV can't be connected
because the AUDIO/VIDEO jack is attached to the cabinet (L)
assembly. To remove the VM-027 board, disconnect the
following connectors.
VM-027 board CN003 (88P, 0.4mm)
*1: DCR-PC120BT/PC120E model only
Note 1: Setting the "Forced VTR Power ON" mode (VTR mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 02, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the VTR power to be turned on
with the cabinet (L) assembly removed.
After completing adjustments, be sure to exit the "Forced Power
ON mode".
Note 2:
Setting the "Forced Camera Power ON" mode (Camera mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the camera power to be turned
on with the cabinet (L) assembly removed.
After completing adjustments, be sure to exit the "Forced Power
ON mode".
Note 3: Setting the "Forced Memory Power ON" mode (Memory mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 05, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the memory power to be turned
on with the cabinet (L) assembly removed.
After completing adjustments, be sure to exit the "Forced Power
ON mode".
Note 4: Exiting the "Forced Power ON" mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.