Table 4B Electrical Specifications H**L Series - Bard H42AA-B Installation Instructions Manual

Table of Contents

Advertisement

No. Field
Rated Volts
MODEL
Power
& Phase
Circuits
H24LA-A00, A0Z
A05
230/208-1
A08
A10
H36LA-A00, A0Z
A05
230/208-1
A10
A15
1 or 2
H42LA-A00, A0Z
A05
230/208-1
A10
A15
1 or 2
H42LA-B00, B0Z
B03
B05
230/208-3
B09
B15
H48LA-A00, A0Z
A05
230/208-1
A10
A15
1 or 2
H48LA-B00, B0Z
B03
B05
230/208-3
B09
B15
H60LA-A00, A0Z
A05
230/208-1
A10
A15
1 or 2
H60LA-B00, B0Z
B03
B05
230/208-3
B09
B15
H72LA-A00, A0Z
A05
230/208-1
A10
A15
1 or 2
H72LA-B00, B0Z
B03
B05
230/208-3
B09
B15
 These "Minimum Circuit Ampacity" values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 310 for power conductor
sizing.
 Maximum size of the time delay fuse or circuit breaker for protection of field wiring conductors.
 Based on 75°C copper wire. All wiring must conform to the National Electrical Code and all local codes.
*
Top outlet supply option is available only factory installed and only on the selected models.
CAUTION:
When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to Note 8 of Table 310 regarding Ampacity
Adjustment Factors when more than three (3) current carrying conductors are in a raceway.
IMPORTANT:
While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses and conductor wires in accordance with the National
Electrical Code and all local codes.
Manual 2100-647D
Page
24 of 36
Electrical Specifications H***L Series
Single Circuit
Maximum
Minimum
External
Field
Circuit
Fuse or
Power
Ampacity
Circuit
Wire Size
Breaker
1
21
30
10
1
30
30
10
1
46
50
8
1
56
60
6
1
29
35
8
1
32
35
8
1
58
60
6
84
90
4
1
32
50
8
1
32
50
8
1
58
60
6
84
90
4
1
25
35
8
1
25
35
8
1
25
35
8
1
33
35
8
1
51
60
6
1
34
50
8
1
34
50
8
1
58
60
6
84
90
4
1
26
35
8
1
26
35
8
1
26
35
8
1
33
35
8
1
51
60
6
1
38
60
8
1
38
60
8
1
60
60
6
86
90
3
1
27
40
8
1
27
40
8
1
27
40
8
1
35
40
8
1
53
60
6
1
58
60
6
1
58
60
6
1
62
70
6
88
90
3
1
40
60
8
1
40
60
8
1
40
60
8
1
40
60
8
1
55
60
6
TABLE 4B
 Minimum
 Maximum
Circuit
External Fuse or
Ampacity
Circuit Breaker
Ground
Wire
Ckt.
Ckt.
Ckt.
A
B
A
10
10
10
10
10
10
10
8
58
26
60
10
10
10
8
58
26
60
10
10
10
10
10
10
10
10
8
58
26
60
10
10
10
10
10
10
10
10
8
60
26
60
10
10
10
10
10
10
10
8
58
26
60
8
58
52
60
10
10
10
10
10
Dual Circuit
Field Power
Ground
Wire Size
Wire Size
Ckt.
Ckt.
Ckt.
Ckt.
B
A
B
A
30
6
10
10
30
6
10
10
30
6
10
10
30
6
10
10
30
6
10
10
60
6
6
10
Ckt.
B
10
10
10
10
10
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents