Table 12 Electrical Specifications W**Ac - Bard W42AC-B Installation Instructions Manual

Wall mount air conditioner
Hide thumbs Also See for W42AC-B:
Table of Contents

Advertisement

Rated
Model
Volts
& Phase
W42AC-A00, A0Z
A05
A10
230/208-1
A15
A20
W42AC-B00, B0Z
B06
B09
230/208-3
B15
B18
W42AC-C00, C0Z
C09
460-3
C15
W48AC-A00, A0Z
A05
A10
230/208-1
A15
A20
W48AC-B00, B0Z
B06
B09
230/208-3
B15
B18
W48AC-C00, C0Z
C09
460-3
C15
W60AC-A00, A0Z
A05
A10
230/208-1
A15
A20
W60AC-B00, B0Z
B06
B09
230/208-3
B15
B18
W60AC-C00, C0Z
C09
460-3
C15
W72AC-A00, A0Z
A05
A10
230/208-1
A15
A20
W72AC-B00, B0Z
B06
B09
230/208-3
B15
B18
W72AC-C00, C0Z
C09
460-3
C15
These "Minimum Circuit Ampacity" values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 310
for power conductor sizing. CAUTION: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special
attention to note 8 of Table 310 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway.
Maximum size of the time delay fuse or circuit breaker for protection of field wiring conductors.
Based on 75°copper wire. All wiring must conform to the National Electrical Code and all local codes.
NOTE: The Maximum Overcurrent Protection (MOCP) value listed is the maximum value as per UL 1995 calculations for MOCP (branch-circuit conductor sizes
in this chart are based on this MOCP). The actual factory-installed overcurrent protective device (circuit breaker) in this model may be lower than the
maximum UL 1995 allowable MOCP value, but still above the UL 1995 minimum calculated value or Minimum Circuit Ampacity (MCA) listed.
IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses and conductor wires in accordance
with the National Electrical Code and all local codes.
Manual 2100-692E
Page
32 of 42
TABLE 12
Electrical Specifications − W**AC Series
Single Circuit
No. Field
Power
Maximum
Minimum
Circuits
External
Circuit
Fuse or Ckt.
Ampacity
Brkr.
1
31
50
1
31
50
1
57
60
1 or 2
83
90
1 or 2
109
125
1
23
35
1
23
35
1
32
35
1
51
60
1
60
60
1
12
15
1
17
20
1
26
30
1
35
50
1
35
50
1
59
60
1 or 2
85
90
1 or 2
111
125
1
26
35
1
26
35
1
33
35
1
51
60
2
N/A
N/A
1
12
15
1
17
20
1
26
30
1
38
50
1
38
50
1
59
60
1 or 2
85
90
1 or 2
111
125
1
28
40
1
28
40
1
34
40
1
52
60
2
N/A
N/A
1
14
20
1
18
20
1
26
30
1
56
60
1
56
60
1 or 2
60
70
1 or 2
86
90
1 or 2
112
125
1
38
50
1
38
50
1
38
50
1
54
60
2
N/A
N/A
1
18
25
1
18
25
1
27
30
Minimum
Field
Circuit
External Fuse or
Power
Ground
Ampacity
Wire
Wire
Ckt.
Ckt.
Size
A
B
8
10
8
10
6
10
4
8
57
26
2
6
57
52
8
10
8
10
8
10
6
10
6
10
14
14
12
12
10
10
8
10
8
10
6
10
4
8
59
26
2
6
59
52
8
10
8
10
8
10
6
10
N/A
N/A
34
28
14
14
12
12
10
10
8
10
8
10
6
10
4
8
59
26
2
6
59
52
8
10
8
10
8
10
6
10
N/A
N/A
34
28
12
12
12
12
10
10
6
10
6
10
6
8
56
26
3
8
60
26
2
6
60
52
8
10
8
10
8
10
6
10
N/A
N/A
38
28
10
10
10
10
10
10
Multiple Circuit
Maximum
Field Power
Ground
Wire Size
Wire Size
Ckt. Breaker
Ckt.
Ckt.
Ckt.
Ckt.
Ckt.
A
B
A
B
A
60
30
6
10
10
60
60
6
6
10
60
30
6
10
10
60
60
6
6
10
40
30
8
10
10
60
30
6
10
10
60
60
6
6
10
40
30
8
10
10
60
30
6
10
10
60
30
6
10
10
60
60
6
6
10
40
30
8
10
10
Ckt.
B
10
10
10
10
10
10
10
10
10
10
10
10