Table 9; Electrical Specifications Q**A4D Series - Bard Q-TEC Q A4D Series Installation Instructions Manual

Packaged air conditioner
Table of Contents

Advertisement

Rated Volts
Model
& Phase
Q36A4DA0Z
-A05
230/208-1
-A10
Q36A4DB0Z
-B06
230/208-3
-B09
-B15
Q36A4DC0Z
-C06
460-3
-C09
-C15
Q42A4DA0Z
-A05
230/208-1
-A10
Q42A4DB0Z
-B06
230/208-3
-B09
-B15
Q42A4DC0Z
-C06
460-3
-C09
-C15
Q48A4DA0Z
-A05
230/208-1
-A10
-A15
Q48A4DB0Z
-B06
230/208-3
-B09
-B15
Q48A4DC0Z
-C06
460-3
-C09
-C15
 These "Minimum Circuit Ampacity" values are to be used for sizing the field power conductors. Refer to the National Electrical code
(latest version), Article 310 for power conductor sizing. CAUTION: When more than one field power circuit is run through one
conduit, the conductors must be derated. Pay special attention to note 8 of Table 310 regarding Ampacity Adjustment Factors
when more than three (3) current carrying conductors are in a raceway.
 Maximum size of the time delay fuse or circuit breaker for protection of field wiring conductors.
 Based on 75°copper wire. All wiring must conform to the National Electrical Code and all local codes.
NOTE: The Maximum Overcurrent Protection (MOCP) value listed is the maximum value as per UL 1995 calculations for MOCP
(branch-circuit conductor sizes in this chart are based on this MOCP). The actual factory-installed overcurrent protective
device (circuit breaker) in this model may be lower than the maximum UL 1995 allowable MOCP value, but still above the
UL 1995 minimum calculated value or Minimum Circuit Ampacity (MCA) listed.
IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses and
conductor wires in accordance with the National Electrical Code and all local codes.
Manual 2100-752C
Page
38 of 41

TABLE 9

Electrical Specifications − Q**A4D Series
Single Circuit
No.
Maximum
Field
Minimum
External
Power
Circuit
Fuse or
Circuits
Ampacity
Ckt. Brkr.
1
26
40
1
31
40
1
57
60
1
20
25
1
23
25
1
32
35
1
50
50
1
11
15
1
12
15
1
16
20
1
25
25
1
31
50
1
31
50
1
57
60
1
24
35
1
24
35
1
32
35
1
51
60
1
11
15
1
12
15
1
16
20
1
25
25
1
33
40
1
33
40
1
57
60
1 or 2
85
90
1
25
30
1
25
30
1
33
40
1
51
60
1
12
15
1
12
15
16
20
1
1
25
30
Minimum
Field
Circuit
Ground
Power
Ampacity
Wire
Wire
Size
Size
Ckt.
Ckt.
A
B
8
10
8
10
6
10
10
10
10
10
8
10
8
10
14
14
14
14
12
12
10
10
8
10
8
10
6
10
8
10
8
10
8
10
6
10
14
14
14
14
12
12
10
10
8
10
8
10
6
10
4
8
57
26
10
10
10
10
8
10
6
10
14
14
14
14
12
12
10
10
Multiple Circuit
Maximum
External Fuse
Field Power
or
Wire Size
Wire Size
Ckt. Brkr.
Ckt.
Ckt.
Ckt.
Ckt.
Ckt.
A
B
A
B
60
30
6
10
10
Ground
Ckt.
A
B
10

Advertisement

Table of Contents
loading

Table of Contents