Cleaning And Maintenance; Burner, Pilot And Control Compartment; Burner Flame - Vermont Castings DVM Series Installation And Operating Instructions Manual

Direct vent gas fireplace
Table of Contents

Advertisement

DVM Series Direct Vent Gas Fireplace
WARNING
Turn off gas before servicing fireplace. It is recommended
that a qualified service technician perform these check-
ups at the beginning of each heating season
BURNER, PILOT AND CONTROL COMPART-
MENT
Keep the control compartment, logs, and burner areas
surrounding the logs clean by vacuuming or brushing at
least twice a year. Make sure the burner porting, pilot air
opening and burner air opening are free of obstructions
at all times.
PILOT FLAME
The flames from the pilot should be visually checked as
soon as the heater is installed and periodically during
normal operation. The pilot flame must always be pres-
ent when the fireplace is in operation. Figure 65. The
pilot flame has three distinct flames, one engulfing the
thermopile, one engulfing the thermocouple or sensor, and
the other reaching to the main burner.
BURNER
Inspect area around the injector. Remove any lint or foreign
material with a brush or vacuum.

BURNER FLAME

The flames from the burner should be visually checked
as soon as the heater is installed and periodically during
normal operation. In normal operation, at full rate, and after
operating for about 15 to 30 minutes, the flame should be
yellow and slightly taller than the rear log. Figure 66
If the flame is blue and only in the center, turn off unit and
let cool. After unit is cool, remove logs and check to make
sure rock wool is placed correctly. Replace logs.
NOTE: The type of installation, vent system configuration,
and wind effects may cause the flame patterns to vary.
44

CLEANING AND MAINTENANCE

Signature Command
System Pilot
Figure 65 -
Pilot Flame
Figure 66 -
Burner Flame Appearance
LG671
DVM log flames
Sensor
Thermopile
FP2453
FP2453
hooded pilot flames
LG671