IBM iSeries 270 Service Manual page 290

Sb2 and sb3 hardware
Table of Contents

Advertisement

7. Multi-adapter bridge domains are labeled PCI Bridge Set inside the tower.
8. The following table provides information necessary to identify the IOP to which IOAs are assigned.
v The left column indicates the domain in which IOA assignment is allowed.
v The right column is used to determine the IOP to which an IOA is assigned.
v The first position in the list must be an IOP. The remaining positions may be IOPs or IOAs. IOAs are
assigned to the first IOP located to their left in the list. Although IOAs can be manually reassigned
using SST/DST, the IOA assignments return to the default order after each IPL.
Table 2. Identify the IOP to which IOAs are assigned
Multi-adapter bridge domain / PCI bridge set
C01 - C04
C05 - C10
C11 - C15
Table 3. FRU locations and failing components for FC 9079 base I/O tower table
Position
FRU name
D01 - D40
Disk unit
D41
Optical
D42
Tape
D46 - D50
Disk unit
NB1
Control panel Control panel
DB3
Device board Device board
DB2
Device board Device board
DB1
Device board Device board
B01 and
AMD
B02
C01
PCI card
278
Hardware (Remove and Replace; Part Locations and Listings)
Possible failing
component
Disk unit
Optical
Tape
Disk unit
AMD
IOP
IOA assignment rules
C01, C02, C03, C04
C05, C06, C07, C08, C09, C10
C11, C12, C13, C14, C15
Type, CCIN, or part
number (use the Type,
model, and part number
list to determine the part
number when the type or
CCIN are given.)
See Type, model, and part
number list.
See Type, model, and part
number list.
See Type, model, and part
number list.
See Type, model, and part
number list.
24L0945
283C (See page 526) or
28CB (See page 528)
283D (See page 526) or
28CC (See page 528)
283D (See page 526) or
28CC (See page 528)
04N3345
2842 (See page 527), 2843
(See page 527), or 2844
(See page 527)
Remove and
replace/recovery
procedure
Go to Recovery procedures.
Go to FC 5074, FC 5079,
FC 9079 - Removable media
- D41 and D42.
Go to FC 5074, FC 5079,
FC 9079 - Removable media
- D41 and D42.
Go to Recovery procedures.
Go to FC 5074, FC 5079 -
Control panel - NB1.
Go to FC 5074, FC 5079,
FC 9079 - Device board -
DB3.
Go to FC 5074, FC 5079,
FC 9079 - Device board -
DB1 and DB2.
Go to FC 5074, FC 5079,
FC 9079 - Device board -
DB1 and DB2.
Go to FC 5074/5079, FC
9074, FC 9079 - AMD - B01
and B02.
Go to Models 840/SB3, FC
8079 (lower half), FC 9079
Cards — Dedicated.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents